PS-0i-MD network connection and program transmission

Time 2023-10-19 23:56 Source:admin Browse:222

1. I/0 channel set to 9

1695285976594.png

2、Set the IP address as shown in the following figure

1695285991219.png

3、Click on<Hidden Port>again to set the port number (TCP) to 8193 in FOCAS2

1695286005540.png

4、Click on the image above<FTP Transfer>, set the connection directory 1, set the IP address of the computer host, username, username to be consistent with the FTP software. The FTP software will be introduced later, and then connect to the set computer.

Page 1: Set computer IP address and username

1695286019740.png

Page 2: Set the directory and folder name of the C drive

1695286032438.png

Click on the (Operation) button, as shown in the following figure. Click on (Select Host), and the connection selection will appear, as shown in the following figure. Previously, the setting for connection 1 was defined, so select connection 1,

1695286051012.png

5、Check if the IP address is connected to the computer host, select the PING key, click on the operation, click on PING FTP1, and the communication status will display: Received response, connected successfully

1695286061717.png

6、The transmission program needs to install the WINDOWS FTP transmission protocol or use the following FTP software

1695286072182.png

Setting method:

1695286081223.png

1695286106206.png

At this point, the network connection is created, and once you enter the machine tool directory, you can observe the program in the computer host as shown in the following figure


1695286138607.png

Program Transfer

Example: Transfer the 02000 program from the computer to the machine tool memory, select<File Input in the CNC MEM directory, enter 2000, click<0 Setting, and click<Running>. If the program name is being transferred in a format other than "0+number", use<F Name>to set the transfer file name

1695286151821.png

Similarly, file output can transfer programs from memory to a computer


Program processing

Processing method:

一、Memory processing

二、CF card processing

  1. Main program call subroutine, M198 external call

  2. 2DNC sets the CF card path and uses external mode processing

三、The network processing mode on the manual has not been successfully tried yet

Copyright © 2022 Shanghai Kunyi Machinery Hardware Co., Ltd.